menu

How to Shutdown / Restart the BYD Battery

  • 0:00
    Alright, here we are at a Gen 24 and a BYD stack and I'm going to run you through the shutdown and restart procedure.
  • 0:11
    You may need to do this if we notify you, or in case of a prolonged power outage, your batteries may turn off, in which case, a full shutdown and restart is what we need to get it going it again.
  • 0:24
    There'll always be a shutdown procedure next to your inverter or battery if we have installed it. So we can just work through that and work back through it to turn it back on.
  • 0:37
    But I'll walk you through it now. First things first is to turn off the main switch inverter supply.
  • 0:43
    There may be an inverter AC isolator if your inverter's too far from the main switchboard. The next step is the PV array DC isolator. It's this switch on the front. It goes to the zero.
  • 0:57
    And as you can see, it can be a little bit sticky. It's spring-loaded to make it effective when it turns off. After we're done that, we move to the battery stack.
  • 1:08
    On the right-hand side of the battery is the battery DC isolator. Just open this cover. There's a little latch. You may have to push down on it to open.
  • 1:19
    From there, you can see there's one big breaker. Up is on, down is off, and you can also see a red indicator. Red means that it's on, and red is for danger.
  • 1:32
    Green means it's off and means safe. So we'll go ahead and turn this off. Then we move over to the push button.
  • 1:42
    We press that and hold it for five seconds until the lights go out. Three, four, five. There we go.
  • 1:54
    Wait then until your inverter lights all turn off. Then we know that it's lost power and we're good to restart.
  • 2:06
    First thing first is to turn the battery back on. Just over to the battery DC isolator and we flick this breaker up.
  • 2:15
    We don't need to worry about the push button on the restart. Next, we go to PV array DC isolator and turn that back on. Wait a couple of seconds, and then we turn on the main switch.
  • 2:30
    Now, you'll see a lot of lights. It takes about two minutes for it to fully restart. But you'll be able to see it back on your monitoring at this point.
  • 2:38
    And you'll see a green light and a blue light if everything's gone to plan and you're back online.

Aliquam morbi in mauris lacinia eu. Volutpat quisque sodales aliquam faucibus. Nunc et velit elementum eget felis. Faucibus dolor metus enim adipiscing consequat. Id quis libero ultricies in. Velit gravida suspendisse cras molestie vel morbi odio. Rhoncus lobortis at diam arcu et eu. Montes rhoncus urna lectus imperdiet. Pulvinar adipiscing facilisis sagittis risus urna faucibus. Integer neque risus orci scelerisque metus in rutrum platea scelerisque. Tincidunt imperdiet velit nunc ut mauris velit viverra quam leo. Tortor porttitor scelerisque erat pellentesque neque dolor. Risus eget odio pretium elit. Convallis parturient nullam urna sem rutrum gravida.

A non sed leo ac tellus in sed. A volutpat eget amet enim suspendisse. Sed curabitur in sit sed ac massa pulvinar. Non non metus morbi vulputate lacus cursus ut. Purus egestas tellus sit in. Posuere neque fusce laoreet enim amet vel iaculis. Cursus mus a diam eleifend ornare suspendisse quam. Sit montes suspendisse vel tincidunt in sit ut facilisis.

At convallis faucibus cursus ullamcorper

1

Turn off the main switch inverter supply
Nunc et velit elementum eget felis. Faucibus dolor metus enim adipiscing consequat. Id quis libero ultricies in. Velit gravida suspendisse cras molestie vel morbi odio. Rhoncus lobortis at diam arcu et eu. Montes rhoncus urna lectus imperdiet.

2

Turn off by switching to zero the PV array DC isolator
Nunc et velit elementum eget felis. Faucibus dolor metus enim adipiscing consequat. Id quis libero ultricies in. Velit gravida suspendisse cras molestie vel morbi odio. Rhoncus lobortis at diam arcu et eu. Montes rhoncus urna lectus imperdiet.

3

Turn off the big breaker of the Battery DC isolator (Press down)
Nunc et velit elementum eget felis. Faucibus dolor metus enim adipiscing consequat. Id quis libero ultricies in. Velit gravida suspendisse cras molestie vel morbi odio. Rhoncus lobortis at diam arcu et eu. Montes rhoncus urna lectus imperdiet.

4

Hold the push button for five seconds.
Nunc et velit elementum eget felis. Faucibus dolor metus enim adipiscing consequat. Id quis libero ultricies in. Velit gravida suspendisse cras molestie vel morbi odio. Rhoncus lobortis at diam arcu et eu. Montes rhoncus urna lectus imperdiet.

5

Turn on the big breaker of the Battery DC isolator (Press Up)
Nunc et velit elementum eget felis. Faucibus dolor metus enim adipiscing consequat. Id quis libero ultricies in. Velit gravida suspendisse cras molestie vel morbi odio. Rhoncus lobortis at diam arcu et eu. Montes rhoncus urna lectus imperdiet.

6

Turn on the PV array DC isolator
Nunc et velit elementum eget felis. Faucibus dolor metus enim adipiscing consequat. Id quis libero ultricies in. Velit gravida suspendisse cras molestie vel morbi odio. Rhoncus lobortis at diam arcu et eu. Montes rhoncus urna lectus imperdiet.

7

Turn on the main switch inverter supply (Press up)
Nunc et velit elementum eget felis. Faucibus dolor metus enim adipiscing consequat. Id quis libero ultricies in. Velit gravida suspendisse cras molestie vel morbi odio. Rhoncus lobortis at diam arcu et eu. Montes rhoncus urna lectus imperdiet.

Committed to delivering clean energy solutions

As Albury Wodonga's leading solar experts, Kdec’s promise of quality service is guaranteed with our roster of trained and licensed Electricians. Whether you’re a commercial business, a new homeowner or looking to upgrade your family home, our 25 years of experience means you’re in safe hands.

Talk to a KDEC team member

Our Office

30 Ruby Court, Albury 2640

Contact Us

  • 02 6021 6033
  • kdec@kdec.com.au
facebook instagram

Quick Links

  • About KDEC
  • KDEC Team
  • Clients & Suppliers
  • Blog
  • KTECH
  • Contact Us
  • FAQ

Our Solutions

  • Solar Solutions
  • Solar Consultancy
  • Electrical Solutions
  • Fibre and Data Solutions
  • EV Chargers

Our Works

  • Industrial
  • Commercial
  • Domestic
  • Fibre and Data
  • Case Studies

Licence Number: NSW 363462C | Vic 29085
© Copyright 2021 by KDEC Electrical. All rights reserved.
Website by Digital Marketer Bee.

KDEC Electrical & Solar
4.9
Based on 102 reviews
powered by Google
js_loader